ABSTRACT
Accumulating evidence suggests that a patient subgroup with severe COVID-19 develops a cytokine release syndrome leading to capillary leakage and organ injury. Recent publications addressing therapy of cytokine storms recommended new extracorporeal therapies such as hemoadsorption. This case report describes a 59-year-old SARS-CoV-2-positive patient with severe ARDS. Due to severe hyperinflammation with concomitant hemodynamic instability and progressive renal failure, combination of continuous renal replacement and CytoSorb® hemoadsorption therapy was initiated. Treatment resulted immediately in a control of the hyperinflammatory response. Simultaneously, lung function continued to improve accompanied by profound hemodynamic stabilization. We report the successful utilization of CytoSorb® hemoadsorption in the treatment of a patient with SARS-CoV-2-induced cytokine storm syndrome.
ABSTRACT
BACKGROUND: The present COVID-19 pandemic has prompted worldwide repurposing of drugs. The aim of the present work was to develop and validate a two-dimensional isotope-dilution liquid chromatrography tandem mass spectrometry (ID-LC-MS/MS) method for accurate quantification of remdesivir and its active metabolite GS-441524, chloroquine, hydroxychloroquine, lopinavir, ritonavir, favipiravir and azithromycin in serum; drugs that have gained attention for repurposing in the treatment of COVID-19. METHODS: Following protein precipitation, samples were separated with a two-dimensional ultra-high performance liquid chromatography (2D-UHPLC) setup, consisting of an online solid phase extraction (SPE) coupled to an analytical column. For quantification, stable isotope-labelled analogues were used as internal standards for all analytes. The method was validated on the basis of the European Medicines Agency bioanalytical method validation protocol. RESULTS: Detuning of lopinavir and ritonavir allowed simultaneous quantification of all analytes with different concentration ranges and sensitivity with a uniform injection volume of 5 µL. The method provided robust validation results with inaccuracy and imprecision values of ≤ 9.59 % and ≤ 11.1 % for all quality controls. CONCLUSION: The presented method is suitable for accurate and simultaneous quantification of remdesivir, its metabolite GS-441525, chloroquine, hydroxychloroquine, lopinavir, ritonavir, favipiravir and azithromycin in human serum. The quantitative assay may be an efficient tool for the therapeutic drug monitoring of these potential drug candidates in COVID-19 patients in order to increase treatment efficacy and safety.